| CONFIGURATION |
TESTING MOLD |
PRM |
CONCLUSION |
| VLT |
Illuminance meter |
≥5% |
5.2% |
| Gloss |
Gloss meter |
≥70° |
86° |
| Self Healing |
Brush the copper 10 times with hot water at 50-70°C for 1 minute |
Invisible/slight |
100.00% |
| Total thickness |
GB/T6672-2001 |
150±5μ |
151μ |
| Stain resistance |
Marker pen, wipe with alcohol after 10seconds |
Slight/no traces |
Extremely slight |
| Coating elongation |
GB/T2792 |
≥70% |
95.0% |
| 180° peel force 24h |
GB/T529 |
≥600 |
926gf |
| Resistant to organic solvents |
Xylene, wipe with alcohol after 10 seconds |
No abnormalities |
Passed |
| Penetration resistance |
Tensile testing machine |
≥100 |
107 |
| Film maximum elongation |
GB/T 1040.1 |
≥200% |
300.0% |